Operating Instructions
Xenotest
®
150 S+

Questions and Answers

  • S
    Sarah ClaytonSep 9, 2025
    What to do if there is overtemperature at the top of the lamp on my Atlas Test Equipment?
    • E
      Elizabeth GutierrezSep 9, 2025
      If there is overtemperature at the top of the lamp on your Atlas Test Equipment, notify Technical Service.
  • T
    Thomas RodriguezAug 22, 2025
    What to do if the water tank is empty in my Atlas Test Equipment?
    • M
      Mary LaraAug 23, 2025
      If the water tank is empty, refill the water reservoir.
  • D
    David Smith MDAug 25, 2025
    What to do if the lid of set is open on my Atlas Test Equipment?
    • L
      Leslie SanchezAug 25, 2025
      If the lid of the set is open on your Atlas Test Equipment, close the device cover.
  • E
    Edward TaylorAug 26, 2025
    What to do if there is no water supply for humidifier in my Atlas Test Equipment?
    • B
      Bradley ZimmermanAug 26, 2025
      If there is no water supply for the humidifier in your Atlas Test Equipment: * Check all tubing connections. * Check the water level in the reservoir.
  • G
    georgetonyAug 27, 2025
    What to do if Atlas Test Equipment displays 'Program parameters not valid'?
    • K
      Karen NelsonAug 28, 2025
      If you see the error message 'Program parameters not valid' after pressing the ENTER key, it might indicate a program intended for a different filter system. If no error message appears, reenter the program.
  • J
    Jason CooperAug 29, 2025
    What to do if Atlas Test Equipment displays 'Program does not exist'?
    • J
      jorge12Aug 29, 2025
      If your Atlas Test Equipment displays 'Program does not exist', enter a test program.
  • A
    Andrew GriffinSep 17, 2025
    What to do if there is no battery or the battery is discharged on my Atlas Test Equipment?
    • K
      Kimberly AcostaSep 17, 2025
      If there is no battery or the battery is discharged on your Atlas Test Equipment, notify Technical Service.
  • F
    Felicia HensonSep 18, 2025
    What to do if the lithium battery is older than 5 years on my Atlas Test Equipment?
    • S
      Susan RuizSep 18, 2025
      If the lithium battery in your Atlas Test Equipment is older than 5 years, inform Technical Service at the next inspection.
  • S
    Sydney RobertsSep 7, 2025
    What to do if the chamber temperature is too high on my Atlas Test Equipment?
    • C
      Casey FisherSep 7, 2025
      If the chamber temperature is too high on your Atlas Test Equipment, notify Technical Service.
  • C
    Christopher MckeeSep 4, 2025
    What to do if my Atlas Test Equipment displays 'Memory error'?
    • C
      Charles RiveraSep 4, 2025
      If your Atlas Test Equipment displays a 'Memory error', notify Technical Service. You can continue using the device. Reenter program, time, and filter system.

Atlas XENOTEST 150 S+ Specifications

General IconGeneral
TypeXenon Test Chamber
Test Chamber Volume100 L
Light SourceXenon Arc Lamp
Lamp Power1500 W
Spectral Range290 - 800 nm
Power Supply230V, 50/60 Hz
ManufacturerAtlas Material Testing Technology
Temperature RangeAmbient to 100°C
Filter SystemsDaylight, Window Glass, UV Filter
Control SystemTouchscreen
Standards MetISO 4892, ASTM G155
Black Panel Temperature Range40°C to 120°C