4. Tilt Detection
5. Flame Detection
Operation method:
4.1 Click to enable the function. When the machine tilts at an angle between 15° and 20° with the hori-
zontal plane, the function is triggered: the machine automatically stops working, the buzzer sounds, and
if there is a display screen, it displays "Machine tilted". If there is no display screen, an alarm prompts on
the PC end.
4.2 There are 3 modes to deactivate the alarm:
4.2.1 No display screen: When the machine returns to a at position, the alarm automatically deactivated.
4.2.2 With display screen: Click "Close" on the display screen to deactivate the alarm.
4.2.3 APP: Prompts "Machine tilted",Click on the phone to close in the prompt box.
(This function is only available on machines with autofocus accessories)
5.1 Precautions:
5.1.1 When using outdoors, direct sunlight may cause false triggering of the function. It is recommended to use indoors.
5.1.2 To turn on/o the ame detection function, control it through the display screen/APP.
5.1.3 When cutting density boards, the ame detection function needs to be turned o to avoid false alarms.
5.2 Operation method:
5.2.1 Click to enable the function. When a re occurs directly below the laser, the function is triggered: the laser automatically returns to the origin of the
machine, buzzer sounds, and the display screen shows "Fire". If there is no display screen, an alarm prompts on the PC end and the buzzer keeps sounding. If
using the APP, it prompts "Flame detected".
5.2.2 The machine can be used normally after turning o and restaing.
4