Configuration Note 4. Configuring Microsoft Lync Server 2010
Version 1.0 Issue 1.0 21 October 2011
4.2 Associating the ‘IP/PSTN Gateway’ with the
Mediation Server
This section describes how to associate the ‘IP/PSTN Gateway’ (E-SBC device) with
the Mediation Server.
¾ To associate the IP/PSTN Gateway with the Mediation Server:
1. Right-click on the Mediation Server to use with the IP/PSTN Gateway (i.e.,
Mediation2.OCSW14.local) and choose Edit Properties.
Figure
4-8: Associating Mediation Server with IP/PSTN Gateway

Table of Contents

Other manuals for AudioCodes Mediant 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 1000 and is the answer not in the manual?

AudioCodes Mediant 1000 Specifications

General IconGeneral
Data link protocolsCAS: MF-R1: T1 CAS, ISDN PRI: ETSI/EURO ISDN, ANSI NI2, QSIG
Security algorithmsHTTPS, SRTP
Authentication methodRADIUS
Internal memory512 MB
Built-in processorCeleron 600 MHz
Processor frequency600 MHz
Internal memory type-
Number of processors installed1
Voice codecsG.711, G.723.1, G.726, G.729A, iLBC
SafetyUL60950-1, FCC 47 CFR
CertificationETS 300019-2-1, ETS 300019-2-2 ETS 300019-2-3
Mounting typeRack mounting
LED indicatorsYes
Power requirements90-260 V AC
Weight and Dimensions IconWeight and Dimensions
Size (imperial)19 \