The behaviour (blinking/illuminated) can be changed via the BLINKER (M1311)
parameter.
7.3 Mechanical position indicator/running indication
Option
Mechanical position indicator:
Continuously indicates the valve position
(For complete travel from OPEN to CLOSED or vice versa, the indicator disc
[2] rotates by approximately 180° to 230°.)
Indicates whether the actuator is running (running indication)
Indicates that the end positions are reached (via indicator mark [3])
Figure 39: Mechanical position indicator
[1] Cover
[2] Indicator disc
[3] Mark
[4] Symbol for position OPEN
[5] Symbol for position CLOSED