13. Putting the AURATON 2020 TX RX
Plus controller into operation for
the first time
1. Put new alkaline batteries to the AURATON
2020 RX Plus controller.
2. Connect the AURATON 2020 RX Plus controller
to the network socket and wait about 10
minutes in order to achieve the full receiver
coverage.
3. The yellow diode " " is lit - the receiver is
accessed by the transmitter. The process is
repeated each minute and lasts about 1
second. No diode signal or blinking diode
indicates insufficient coverage.
Note: Coverage of the device is strongly
affected by the materials used for construction
of the building. In an open area the AURATON
2020 TX Plus connected with the AURATON
2020 RX Plus receiver should cover the
distance up to 100m.
In buildings the coverage should reach 30m
which is equivalent to penetration through
several stories. In ferroconcrete structures the
signal is strongly damped resulting in reduced
coverage of the equipment.
Note: The AURATON 2020 TX RX Plus kit is
set to the “085” communication code, being
ready for operation upon the first installation.
Nevertheless, in case of any communication
problems between the TX controller and RX
receiver refer to Section 11 – Setting a new
communication code.
4. The red diode " " lit indicates proper
connection of the AURATON 2020 RX Plus
receiver to 230V network.
5. The green diode " " it indicates that the
executive device (e.g. a furnace) is operative.
49
EN
Putting the AURATON 2020 TX RX Plus controller into operation for the first time