EasyManua.ls Logo

AutomationDirect DURAPULSE Series - Page 71

AutomationDirect DURAPULSE Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4–3
Parameter Summary
Parameter
*
Description Range*
Default
Setting
User
Setting
Ramp Parameters
P1.00
Stop Methods
00: Ramp to Stop
01: Coast to Stop
00
P1.01
Acceleration Time 1 0.1 to 600.0s (must be > 1s to be effective) 10.0
P1.02
Deceleration Time 1 0.1 to 600.0s (must be > 1s to be effective) 30.0
P1.03
Accel S-curve 0 to 7 00
P1.04
Decel S-curve 0 to 7 00
P1.05
Acceleration Time 2 0.1 to 600.0s (must be > 1s to be effective) 10.0
P1.06
Deceleration Time 2 0.1 to 600.0s (must be > 1s to be effective) 30.0
P1.07
Select method to use
2nd Accel/Decel
00: RMP2 from DI terminal
01: Transition Frequencies P1.08 & P1.09
00
P1.08
Accel 1 to Accel 2
frequency transition
0.0 to 400.0 Hz 0.0
P1.09
Decel 2 to Decel 1
frequency transition
0.0 to 400.0 Hz 0.0
P1.10
Skip Frequency 1 0.0 to 400.0 Hz 0.0
P1.11
Skip Frequency 2 0.0 to 400.0 Hz 0.0
P1.12
Skip Frequency 3 0.0 to 400.0 Hz 0.0
P1.13
Skip Frequency 4 0.0 to 400.0 Hz 0.0
P1.14
Skip Frequency 5 0.0 to 400.0 Hz 0.0
P1.17
Skip Frequency Band 0.0 to 20.0 Hz 0.0
P1.18
DC Injection Current Level 00 to 100 % 00
P1.20
DC Injection during Start-up 0.0 to 5.0 sec 0.0
P1.21
DC Injection during Stopping 0.0 to 25.0 sec 0.0
P1.22
Start-point for DC Injection 0.0 to 60.0 Hz 0.0
* Some parameters and settings are available only in later firmware versions of DURAPULSE drives. Refer to
the beginning of this “DURA
PULSE Parameter Summary” section for more information.
Parameter can be set during RUN Mode.
Chapter 4: AC Drive Parameters
DURAPULSE AC Drive User Manual
1st Ed. Rev. D 05/2013

Table of Contents

Related product manuals