Chapter 4: AC Drive Parameters
4–4
Parameter Summary (continued)
Parameter
*
Description Range*
Default
Setting
User
Setting
Volts/Hertz Parameters
P2.00
Volts/Hertz Settings
00: General Purpose
01: High Starting Torque
02: Fans and Pumps
03: Custom
00
P2.01
Slip Compensation 0.0 to 10.0
0.0 (V/Hz mode)
1.0 (Vector mode)
P2.02
Auto-torque Boost 00 to 10 00
P2.03
Torque Compensation
Time Constant
00 to 10 sec 0.05
P2.04
Mid-point Frequency 0.1 to 400 Hz 0.5
P2.05
Mid-point Voltage
230V class: 0.1 to 240V
460V class: 0.1 to 480V
5.0
10.0
P2.06
Min. Output Frequency 0.1 to 20.0 Hz 0.5
P2.07
Min. Output Voltage
230V class: 0.1 to 50V
460V class: 0.1 to 100V
5.0
10.0
P2.08
PWM Carrier Frequency
01 to 15 kHz
01 to 15 kHz
01 to 09 kHz
01 to 06 kHz
1–5hp = 15
7.5–25hp = 9
30–60hp = 6
75–100hp = 6
P2.09
Slip Compensation
Time Constant
0.05 to 10.00 sec 0.10
P2.10
Control Mode
00: V/Hz without
encoder feedback
01: V/Hz with encoder feedback
02: Sensorless Vector without
encoder feedback
03: Sensorless Vector with
encoder feedback
04: V/Hz with encoder feedback
& high-speed regulation
05: Sensorless Vector with
encoder feedback
& high-speed regulation
00
* Some parameters and settings are available only in later firmware versions of DURAPULSE drives. Refer to
the beginning of this “DURA
PULSE Parameter Summary” section for more information.
Parameter can be set during RUN Mode.
DURAPULSE AC Drive User Manual
1st Ed. Rev. D 05/2013