Chapter 4: AC Drive Parameters
4–22
Skip Frequency 1 Default Setting: 0.0
Range: 0.0 to 400.0Hz
Skip Frequency 2 Default Setting: 0.0
Range: 0.0 to 400.0Hz
Skip Frequency 3 Default Setting: 0.0
Range: 0.0 to 400.0 Hz
• P1.10, P1.11, and P1.12 determine the location of the frequency bands that will
be skipped during AC drive operation.
Skip Frequency 4 Default Setting: 0.0
Range: 0.0 to 400.0 Hz
Skip Frequency 5 Default Setting: 0.0
Range: 0.0 to 400.0 Hz
Skip Frequency Band Default Setting: 0.0
Range: 0.0 to 20.0 Hz
This parameter determines the frequency band for a given Skip Frequency (P1.10,
P1.11, or P1.12). Half of the Skip Frequency Band is above the Skip Frequency
and the other half is below. Programming this parameter to 0.0 disables all skip
frequencies.
Output frequency
Skip Frequency 1
P 1.10
Skip Frequency 2
P 1.11
Skip Frequency 3
P 1.12
Skip Frequency
Set Point
Skip Frequency Band
P 1.17
P1.17
P1.14
P1.13
P1.12
P1.11
P1.10
DURAPULSE AC Drive User Manual
1st Ed. Rev. D 05/2013