LCD Display Timer
Reset
Power On
RUN mode
Function
setting mode
Setting time
change mode
Checking
output
contact status
for 3sec
for 3 sec
while pressing
※
If changing function setting,
operation will stop.
※
LE4SA only.
: Enabled mode : Disabled mode
Function and Time Setting
Configuration
● Reset
Reset using in Run mode
● Run mode
The operation status (when power is on for the rst time: factory default setting) is displayed.
It could enter into function setting mode, setting value change mode and output contact status mode.
● Function setting mode
If pressing over 3 sec in the Run mode, it will enter into function setting mode and if pressing over 3 sec in function
setting mode, it will return to Run mode.
※
Even if it enters into function setting mode in Run mode, time progressing and output control will continue.
※
If operation settings are changed in function setting mode, all outputs will be o and reset on returning to run mode.
● Output contact status mode (LE4SA only)
Output contact status are displayed while pressing in Run mode.
※
If pressing over 3 sec, it will enter into function setting mode.
● Setting time change mode
Press to enter into setting time change mode and press to return to Run mode.
Even if signal is input when changing setting time, time progressing and output control will be continue.
If no key is pressed over 60 sec in setting time change mode, it will return to Run mode.
※
If no key is pressed over 60 sec in setting time change mode, it will return to Run mode and previous parameter value is
not stored.