EasyManua.ls Logo

Autonics TM4 Series - Wiring Precautions

Autonics TM4 Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Modbus Mapping Table
© Copyright Reserved Autonics Co., Ltd. 35
2.5.8 Digital iput setting group (Func: 03/06/16, RW: R/W)
No(Address)
Parameter
Description
Setting range
Unit
Factory
default
TM2
TM4
40
0573(024C)
-
Digital Input 1 Func
Digital input terminal 1
function
0: OFF 1: STOP
2: AL
-
RESET 3: MANUAL
4: MULTI
-SV
-
0
40
0574(024D)
-
Digital Input 2 Func
Digital input terminal 2
function
0: OFF 1: STOP
2: AL
-
RESET 3: MANUAL
4: MULTI
-SV
-
0
40
0575(024E)
-
Digital Input 1
Ch
Digital input terminal 1
target channel
0: CH1 1: CH2
-
0
40
0576(024F)
-
Digital Input 2
Ch
Digital input terminal 2
target channel
0: CH1 1: CH2
-
1
40
0577(0250)
to
40
0600(0257)
-
Reserved

Other manuals for Autonics TM4 Series

Related product manuals