AUTOOL Autool BT360 Battery System Tester
15
ripple test result and charging test result.
NOTE: If no increase rotation detected, it shall be the fault of
generator regulator or connection with battery failed. Tester will try 3
times to further detect, if still failed, it will skip the increase rotation
detect and the test result displays "No Volt Output". See below:
Check the connection between generator and battery, then retest.
Charging Test Result:
1) Charging Volt: Normal
Charging system shows the generator output normal, no problem
detected.
2) Charging Volt: Low
Charging volt of the charging system is low.
Check drive belt of the generator whether slip or running off. Check
the connection between generator and battery is normal or not.
If both of the drive belt and the connection are in good condition,
follow the manufacturer's suggestion to eliminate generator fault.
3) Charging Volt: High
Generator output volt is high.
Since most of the vehicle generators are using internal regulator, the
generator assembly has to be replaced.(Some old style cars are
using external regulator, then directly replace the regulator.)
The normal high volt of the voltage regulator is maximum
14.7±0.5V.If charging volt is too high, it will overcharge the battery.
Therefore the battery life will be shortened and troubles will be

Other manuals for Autool BT360