22
Operation Details
Main functions note
Remark Tr Tr means indoor environmental temperature
Te Te means indoor temperature of evaporator
Ts Ts means temperature setting
Tc Tc means outdoor temperature of evaporator
Td Td means discharge temperature of compressor
Ta Ta means outdoor environmental temperature
1. Emergency mode
When it is shut down, the air conditioner will open and operate in automatic mode upon
pressing the emergency mode, the default settings for the throttle is swing, and the default
settings for wind speed is automatic wind; while it is open, it will shutdown automatic
according to different modes upon pressing the emergency button.
2. Automatic mode
When choosing the automatic mode of the remote controller, the running lights flashing 20s,
selected the running mode for system, the pattern determine the wind speed within 20s weak
wind operation, the throttle put to refrigeration reference point, the compressor will controlled
by fuzzy control pattern; The air conditioner automatically select cooling, dehumidification,
heating mode in accordance with the indoor temperature.
1 when Tr26,choosing cooling mode and running according to cooling mode,
temperature setting is 24.
2 when 25Tr26,choosing cooling mode and running according to cooling mode,
temperature setting is Tr - 2.
3 when 23Tr 25, choosing dehumidification mode and running according to
dehumidification mode, temperature setting is Tr - 2
4 when Tr 23,choosing heating mode and running according to heating mode,
temperature setting is 26.
5The functions of this model are as follows: time setting, sleep, auto start, Anion, I feel and
so on.
6After selecting the system mode, it won’t change according to the indoor temperature in the
circumstances of keeping
compressor not opened consecutive time < 2 hour; if the
compressor not opened consecutive time 2h,it will select the
running mode again.
7Wind speed and the throttle determined by the remote controller.
8Opening it again after shut down, The air conditioner will select the running mode again.
3. Cooling mode
1Temperature setting is determined by the remote controller, the range of temperature is
16℃~32,temperature setting accuracy:
temperature±1,adjusting the temperature setting through the button of“ temperature higher”
and“ temperature lower”Controller determine the running condition and speed of indoor fan
through fuzzy control according to not only the gap between the current indoor temperature
and temperature setting, but also the rate of change of temperature, in order to get the best
running condition.
2Start frequency of compressor:20HZ
3Movement rate of operating frequency:1Hz/s
After start of compressor, it will operate stably at 60Hz 60s.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX ASW-H09A4/SAR1DI and is the answer not in the manual?

AUX ASW-H09A4/SAR1DI Specifications

General IconGeneral
BrandAUX
ModelASW-H09A4/SAR1DI
CategoryAir Conditioner
LanguageEnglish

Related product manuals