The highest frequency should be 60Hz and indoor motor blow the low wind speed at the
heating & sleep mode.
Temperature
setting Temperature 降低 2
再降低 2
28
1h 2h 7hend the sleepoff
NINE Timing
The highest timing should be 24h,1min as unit,can’t cancel timing at the single timing
and no change to mode and indicator light run when timing has been made.
1Timing for being off
Can only work the timing function which fall within the range from 1min to 24h when
air-conditioner run and then will shut down when the timing is over.
2Timing for being on
Can only work the timing function which fall within the range from 1min to 24h when
air-conditioner shut down and then will run when the timing is over.
The former timing and sleep functions will be canceled automaticly when you intend to run or
shut down after timing.
8. Test Yourself
1Test yourself procedure of indoor unit
Force to run and get to the test yourself procedure when buzzer ring for 2 short timesÆDigital
pipe and 3 indicator lights workÆDigital pipe display respectively “11”“22”“33”“44” for
1sÆLight run for 1sÆTiming run for 1sÆSleep light run for 1sÆStep motor run for 1sÆindoor
motor run for 1s at its full wind speedÆBuzzer ring for 1 short timeÆAir-conditioner go to
sleep and end test yourself procedure.
2Test yourself procedure of outdoor unit
Force to run(CN6 get through outdoor electrical board),get to the test yourself procedureÆtest
EEPROMÆtest temperature sensorÆtest communication of indoor and outdoor unitsÆtest
communication between module and outdoor unitÆtest each outputÆair-conditioner go to
sleep and end test yourself procedure.
9. The Protection Function Of Fault Instruction
1The over-current protection:
total current 9A the compressor stops;
8A total current <9 A the compressor reduce operating frequency, if the current is
still more than 8A when the frequency is down to 35 Hz, then the
compressor will stop to work;
7A total current <8 A in this area the compressor prohibit from increasing the frequency;
The overall current <7A in this area the compressor operate normally
2Anti-freeze protection of indoor coil while cooling and dehumidification
Te decline:
if 5 <Te <9 , ℃℃ the compressor frequency remains unchanged if Te 5 ,
the frequency of the compressor will decline in the rate of 1Hz/10s
Te rise:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX ASW-H09A4/SAR1DI and is the answer not in the manual?

AUX ASW-H09A4/SAR1DI Specifications

General IconGeneral
BrandAUX
ModelASW-H09A4/SAR1DI
CategoryAir Conditioner
LanguageEnglish

Related product manuals