Position 6, (full opening) position 5 (heating base point ) position 4( refrigerating waving
end) position 3( heating waving end) position 2 (refrigerating base point) position 1 (full
closing)
11. Wind Speed Choosing Function
When running normally, wind speed will work as normal controlling speed for every model.
Unit; r/min
Wind speed button high wind middle wind low wind breeze
Refrigerating speed 1080 1000 920 (frequency<= 50Hz) 650
Heating speed 1080 1000 920 (frequency<= 60Hz) 650
12. “Black-Out Mode Function”
1 Setting method: controller ”black-out mode function” setting method is that after controller
is connected to electricity, press the sleeping button ten times within 8s with remote control
towards controller, if this function is set successfully, buzzer will make sound four times. If
want to cancel this memory function , operate as before, press the sleeping button ten times
within 8s with remote control towards controller,, if buzzer sounds twice, canceling is ok, if no
sound for buzzer , it fail to cancel.
2 Content for memory function: running model, setting wind speed, Ts, waving status and
turning on /turning off status.
3 If”black-out mode function” is set successfully, power is missing after turning off normally,
then connect it to electricity and turn on, compressor will have no 3min extending protection, if
stop power when turning on, then 3min extending protection will works after reconnect power
and turn on .
4 After”black-out mode function” is ok, If sleeping function or timing function are set
before power is missing, then status for controller will acquiesce turning off status after
reconnecting to electricity
13. Negative Ion Function
In case that indoor motor starts up, press the Negative ion function button on the remote
control, then negative ion electrical apparatus on the controller open, the whole machine will
33

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX ASW-H09A4/SAR1DI and is the answer not in the manual?

AUX ASW-H09A4/SAR1DI Specifications

General IconGeneral
BrandAUX
ModelASW-H09A4/SAR1DI
CategoryAir Conditioner
LanguageEnglish

Related product manuals