Environmental.
Issue 1 July 2006 227
Environmental.
Note:
Note: The C364T NEBS complies to the NEBS standard
Safety
UL listed to UL60950-1.
C-UL (UL for Canada) certified to CAN/CSA-C22.2 No. 60950-0-03.
CE for Europe approved according to EN 60950 and IEC 60950-1.
Laser components are Laser Class I approved:
- EN-60825/IEC-825 for Europe
- FDA CFR 1040 for USA
Branch Circuit Protection: A UL Listed and CSA Certified 15A branch circuit protective
device is to be provided in the building AC mains wiring installation.
C364T C364T-NEBS C364T-PWR
Input voltage 100 to 240 VAC
50/60 Hz
-36 to -60 VDC 100 to 240 VAC
50/60 Hz
Power
dissipation
90 W max 90 W max 760 W max
AC Input current 1.3 A max N/A 7.6 A max
DC Input
current‘
2 A max 2 A max 15 A max
Operating Temp. 0° to 40°C (32° to 104°F)
Storage Temp. -40° to 70°C (-14° to 184°F)
Rel. Humidity 5% to 95% non-condensing