Power Failure and Battery Fault
Monitoring
The BOSS controller has built in external power and backup battery monitoring. To use this fea-
ture, fault monitoring needs to be enabled in conguration app (see page 18). Incoming power will
be paralleled to the power fault input relay on the BOSS. The battery terminals from the RATH by
AVIRE 1000 power supply will be paralleled to the battery input relay on BOSS. When in fault the
System Fault Relay output will change state. This application is only recommended to be used with
the RATH by AVIRE
1000 power supply.
BOSS System Monitoring Hardware Overview
1. System fault relay output- Changes state when any fault occurs
on system.
2. Call Box active call relay output- Changes state if any call box is
attempting a call
3. Power supply fault input- Monitors Input Power
4. Battery fault input- Monitors Backup Battery
5. Cable strain relief
6. IEC power supply input
7. Power supply fuse
Wiring Diagram
Line: Black or Brown
Neutral: White or Blue
Ground: Green or Yellow/Green
120V
Relay
Primary
Power Loss
L
G
N
AC OUT
GROUND
DC +
DC -
BOSS
BATTERY
DC +DC -
0
115
BACK OF BOSS CONTROLLER
V+ V- V+ V-
5-230vac
Input
18ga
Recommended
18ga
Recommended
1000 POWER SUPPLY