Page #57 background image
43
CHAPTER
5
CPS Appliance Commands
Connect Command
The Connect command establishes a connection from the CPS serial over IP network appliance
serial CLI port to a device attached to another port on that CPS appliance. To use this command,
you must have previously issued a Server CLI command with the Connect=On parameter. For
more information, see Connecting to Serial Devices on page 13.
Access right: port-specific
Access level: ADMIN, APPLIANCEADMIN or others with access to port
Syntax
CONNECT <port>
Example
The following command establishes a connection from the serial CLI port to port 6.
> connect 6
Disconnect Command
The Disconnect command terminates a session with a serial device that was previously initiated
with a Connect command. This command frees the attached serial device and allows other users to
access it.
Access right: port-specific
Access level: ADMIN, APPLIANCEADMIN or others with access to port
Syntax
DISCONNECT
Table 5.1: Connect Command Parameter
Parameter Description
<port> Port number in the range 1-8 for a CPS810 appliance or 1-16 for a CPS1610 appliance.