AXISQ1932–EThermalNetworkCamera
Aboutsystemoptions
ToclearallrecordingsanddatafromtheAxisproduct’sfolderonthedesignatedshare,clickClearunderStorageTools.
Toavoidllingtheshare,itisrecommendedtoremoverecordingscontinuously.UnderRecordingSettings,selectRemoverecordings
olderthanandselectthenumberofdaysorweeks.
Tostopwritingtotheshareandprotectrecordingsfrombeingremoved,selectLockunderRecordingSettings.
Ports&Devices
I/OPorts
TheAxisproductprovidestwocongurableinputandoutputportsforconnectionofexternaldevices.AnAxismulticableisrequired
whenconnectingexternaldevices,seeMulticableconnectorsonpage55.
ToconguretheI/Oports,gotoSystemOptions>Ports&Devices>I/OPorts.Eachportcanfunctionasinputoroutput:
InputasOpencircuitTheinputbecomesactivewhenthecircuitisgroundedby,forexample,aREXdevice.Itremains
inactiveaslongasitsnormalstateequalsitscurrentstatus.
InputasGroundedcircuitTheinputbecomesactivewhenthecircuitisopenedbyforexampleamonitor.
OutputasOpencircuitTheoutputportisinanon-conductivestatewhenitscurrentstatusisopencircuit.Thecurrent
statusofanoutputportcanbechangedby,forexample,anactionrule.
OutputasGroundedcircuitTheoutputportisinaconductivestatewhenitscurrentstatusisgroundedcircuit.
PortStatus
ThelistontheSystemOptions>Ports&Devices>PortStatuspageshowsthestatusoftheproduct’sinputandoutputports.
Note
AnAxismulticableisrequiredwhenconnectingI/OdevicestotheAxisproduct.SeeMulticableconnectorsonpage55.
Maintenance
TheAxisproductprovidesseveralmaintenancefunctions.TheseareavailableunderSystemOptions>Maintenance.
ClickRestarttoperformacorrectrestartiftheAxisproductisnotbehavingasexpected.Thiswillnotaffectanyofthecurrent
settings.
Note
ArestartclearsallentriesintheServerReport.
ClickRestoretoresetmostsettingstothefactorydefaultvalues.Thefollowingsettingsarenotaffected:
thebootprotocol(DHCPorstatic)
thestaticIPaddress
thedefaultrouter
thesubnetmask
thesystemtime
theIEEE802.1Xsettings
Note
IftheAxisproductisrestored,uploadedapplicationsandtheirsettingsareremoved.
47