EasyManua.ls Logo

Bacharach Portable Combustion Analyzer - Page 32

Bacharach Portable Combustion Analyzer
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
PCA
TABLE 4-1. COMMA-DELIMITED FIELDS
Field
Data Name or Value
Label
in
Column
Headings
1
Instrument serial number
S
N
2
ID line 1 (up to 16 characters)
ID1
3
ID line 2 (up to 16 characters)
ID2
4
ID line 3 (up to 16 characters)
ID3
5
Time of
test (hh:mm:ss)
TIME
6
Date of test (dd.mm.yyyy)
DATE
7
1
Name of fuel (up
to 16
characters)
FUEL
8
1
Flue gas temperature
T
S
9
1
Air temperature
T
A
10
1
Temperature unit of measure (°F or °C)
C/
F
11
1
O
2
concentration in %
O2
12
1
CO
2
concentration in %
C2
13
1,2
CO concentration in ppm
CO
14
1,2
CO referenced to nn% O
2
in ppm
C
F
15
1,3
NO concentration in ppm
N
X
16
1,3
NO referenced to nn% O
2
in ppm
N
F
17
1,2
O
2
Reference used in fields 14 and 16
O2R
18
1
Combustion efficiency in %
E
F
19
1
Excess air in %
EA
20
Draft measurement
D
R
21
Draft unit
of meas
ure
MB/PA/WC
1
Empty data field for draft tests
2
Empty data field for PCA Models 10, 15, 40 and 45
3
Empty data field for PCA Models 10, 15, 20, 25, 40, 45, 50, and 55
TABLE 4-2. TYPICAL SPREADSHEET FOR A PCA 65
SN ID1 ID2 ID3 TIME DATE FUEL TS TA C/F O2
AX1020 ID LINE 1 ID LINE 2 ID LINE 3 9:03:27 PM 2/24/1999 NATGAS 374 68 F 4
AX1020 ID LINE 1 ID LINE 2 ID LINE 3 9:10:35 PM 2/24/1999
C2 CO CF NX NF O2R EF EA DR MB/PA/WC
9.5 12 13 10 11 3 82.2 21 -0.25 WC
-0.25 WC
Line 1: Column Headings
Line 2: Typical Combustion Readings
Line 3: Typical Draft Readings
4-16
Instruction 0024-9219

Table of Contents

Related product manuals