BATTERY REPLACEMENT
Battery powered monitors use a single 3.6V DC D size, lithium battery. When replacement is necessary, use a clean fresh
battery to ensure continued trouble-free operation.
Replacement Batteries
Manufacturer Part Number
Badger Meter B300028
Xeno S11-0205-10-03
Tadiran TL-5930/F
2. Unscrew the four captive screws on the front panel to gain access to the battery (see Figure 17).
Freq. In
4-20mA
Iso Total Pluse
TR_B
TR_A
RS485 Gnd
Setpoint 1
Setpoint 2
Gnd
+
–
+
–
+
–
Total Reset
OC Total Pluse
Signal Gnd
+ –
KB/Display
J1
TB1
JP1
JP2
JP3
P2
Input Total Pulse Signal
P1
Mag
Pulse
Iso
OC
Low
High
2
1
Unscrew
Captive Screws
Figure 17: Opening the
3. Press the tab on the battery connector to release it from the circuit board (see Figure 18).
Freq. In
4-20mA
Iso Total Pluse
TR_B
TR_A
RS485 Gnd
Setpoint 1
Setpoint 2
Gnd
+
–
+
–
+
–
Total Reset
OC Total Pluse
Signal Gnd
+ –
KB/Display
J1
TB1
JP1
JP2
JP3
P2
Input Total Pulse Signal
P1
Mag
Pulse
Iso
OC
Low
High
TR-A
TR-B
RS485 Gnd
Setpoint 1
Setpoint 2
Gnd
+
+
-
+
-
-
Total Reset
OC Total Pulse
Signal Gnd
Freq. In
4-20 mA
ISO Total Pulse
WARNING- To reduce the risk of ignition
of a ammable atmosphere, batteries
must only be changed in an area known
to be nonammable.
REPLACE BATTER WITH
XEON S11-0205-10-03
OR TADIRAN TL-5930/F ONLY
Battery
Connector
Press
Release
Tab
Slide
Connector
Away
Figure 18: Battery connection release.
4. Remove the old battery and replace it with new one.
5. Re-fasten the front panel screws.
Battery Replacement