to be installed for the function to be used (see
the manual for the vehicle, boat or building).
Fault messages
If an error occurs in the system, the display will
show the reason. This is only displayed when
the panel is on standby.
Battery too low: If the vehicle, boat or building
has a battery voltage of less than 10.5V, the
boiler stops. It is automatically reset when the
voltage reaches 11V.
Fan failure: Faulty fan speed. In order to reset,
disconnect 12V from the boiler and reconnect
(automatic reset after 5 minutes).
Gas failure: Gas nished. Reset by switching
off and restarting the boiler in accordance with
item 1.
Overheat red fail: Overheating protection (red
cable) triggered. To reset, disconnect 12V from
the boiler and reconnect.
Overheat blue fail: Overheating protection
(blue cable) triggered. To reset, disconnect 12V
from the boiler and reconnect.
Window open: Window open, the boiler stops
for gas. Gas operation in the boiler starts
again when the window is closed. The electrical
operation remains in function. Check the
vehicle, boat or building manual to see whether
this function is installed.
Connection failure: There is a connection fault
between boiler and panel.
To reset, disconnect 12V from the boiler and
reconnect.