may be installed. The storage rack is a piece
of extra equipment and may be obtained from
Dometic.
Exchange of the igniter’s battery
Unlock the battery by depressing and turning
the button (c) approximately 90 degrees
clockwise.
Remove cap and exchange battery (1.5V AAA/
R3/Micro) Observe polarity.
Shutting off the refrigerator
Set energy selector switch A to position ‘OFF’.
The appliance is switched off.
Release the locking mechanism of the door
lock by pushing it and shift it to the front. If
the door is shut in this position, a small gap
is nevertheless kept open to prevent formation
of mildew. If the refrigerator is to be taken out
of service for an extended period of time, close
the on-board shut-off valve and the cylinder
valve.
Lighting
If the door is open for more than two minutes,
the sensor- controlled interior lighting is
automatically cut off (except for models with
battery ignitor.)
Dometic Refrigerator Model RMD8501
Cleaning
Before starting up the refrigerator, it is
recommended to clean inside and repeat this
at regular intervals. Using a soft cloth and
lukewarm water with a mild detergent. Then
wipe out the appliance with clean water and
dry thoroughly.
To avoid deterioration of materials:
Do not use soap or hard, abrasive or
soda-based cleaning agents.
Do not allow the door seal to come into
contact with oil or grease.
Operating modes and use of the refrigerator:
Operation mode and use of the refrigerator
This refrigerator is equipped to operate
on three power modes: AC mains power
(230V) 12V DC or gas (propane/butane
liquid gas)
Select the desired power mode by
the MODE button. Appliances with
automatic energy selection (AES) are
additionally provided with “automatic
mode” function. The AES system
automatically selects the best energy
source for each particular situation.
Maintenance
In compliance with the applicable regulations,
please note that the gas unit and the
connected ventilation ducts must be checked
by authorised technical personnel after rst
use and after every other year for compliance
with the European Standard EN 1949. A test
certicate has to be issued. It is the user’s
responsibility to arrange this test.
The gas burner must be inspected and cleaned
as necessary at least once a year. When using
liquid petroleum gas (tank or rell cylinders)
the maintenance interval is reduced to half-
yearly or quarterly.
Keep the evidence of maintenance work
carried out on your refrigerator.
Work on gas and electrical equipment shall be
carried out by an authorised customer services
department.