Troubleshooting
Before notifying the authorised Service Centre,
please check whether:
The instructions in the section “Operating the
refrigerator” have been followed.
The refrigerator is level.
It is possible to operate the refrigerator with
any available power source.
Failure: The refrigerator does not cool
sufciently.
Possible cause
Action you can take
q) Inadequate ventilation to the
unit.
a) Check that the ventilation grilles are not
covered.
q) Thermostat setting is too low.
a) Set Thermostat to a higher level.
q) The condenser is heavily frosted.
a) Check that the refrigerator door closes
properly.
q) Too much warm food has been
stored
a) Allow warm food to cool down before
storage.
q) The appliance has been running for only
inside within short period of time.
a) Check whether the cooling compartment
works after 4 – 5 hours.
q) Ambient temperatures too high.
a) Regularly remove ventilation grilles.
Failure: The refrigerator does not cool in gas
operation mode.
Possible cause
Action you can take
q) Gas cylinder empty.
a) Change gas cylinder.
q) Is the supply shut-off device open?
a) Open the shut-off device.
q) Air in the gas pipe?
a) Switch off the appliance and start again.
Repeat this procedure 3-4 times, if necessary.
Failure: The refrigerator does not cool in 12V
operation.
Possible cause
Action you can take
q) On-board fuse defective.
a) Fit new fuse.
q) On-board battery discharged.
a) Check battery, charge it.
q) Engine not running.
a) Start engine.
q) Heating element defective (please also refer
to failure indication).
a) Please inform the Dometic Customer
Services.
Failure: The refrigerator does not cool in
230V operation.
Possible cause
Action you can take
q)On-board fuse defective.
a) Fit new fuse.
q) No connection to supply voltage.
a) Establish power connection.
q) AES: gas operation despite connection to
the supply voltage.
a) Appliance switches to gas operation due
to insufcient supply voltage (automatically
switches back to 230V operation).
q) Heating element defective (please also refer
to failure indication)
a) Please inform Dometic Customer Services.
75
6
FITTED EQUIPMENT- Refrigerators
FITTED EQUIPMENT- Refrigerators

Table of Contents