EasyManua.ls Logo

Balluff BNI EIP-502-105-Z015 - 7.10. Module information; 7.11. General Informations

Balluff BNI EIP-502-105-Z015
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Balluff Network Interface EtherNet/IP, BNI EIP-502-105-Z015
www.balluff.com
16
7 Display
7.10. Module
information
By short-time keypress on arrow key you can scroll through module information
menu.
Informations are the product name, the module revisions and the MacID.
7.11. General
Informations
Longtime keypress for „fast scrolling“ in editing mode
10 secondes without keypress results in leaving actual screen and entering the
default screen mode (4
th
octet of ip address). Unsaved changes gets lost
Differences between new configuration and the configuration the module is working
with are shown by a unequal-symbol. In this case the time to default screen is only
5 seconds.
In editing mode the screen flashes. In fast scroll mode the screen is flickering
If the module receives a single ping, the word “ping” is shown in the display screen
for a few seconds. Afterwards the screen is reset to the screen which had been
shown before. By short-time key press on set key the ping-mode can be left
preterm.
If the module receives a double ping, the word “ping” is shown in the display. This
screen can be left only by short-time key press on set key. The screen shown
before ping gets viewed again.
The Led function at the display leds can be defined user specific ba setting some
bits in the process data inputs. (see Bitlayout, chapter 8 „Annex“)
The function plc-lock can also be used by setting a bit in the process data inputs.
(see Bitlayout, chapter 8 „Annex“)
Note:
Editing mode can not be chosen in display if the plc lock bit in process data
inputs is (see Bitlayout, chapter 8 „Annex“)
BNI