www.balluff.com
Sensors Worldwide
Technical Description / User’s Guide
BTL5-A/C/E/G__-M____-B/Z-S32/KA__
Micropulse Linear Transducer
Analog Output-Rod Style
Z_Analog_122003_cover.pmd 12/11/2003, 3:46 PM1
Question and Answer IconNeed help?

Do you have a question about the Balluff Micropulse BTL5-A series and is the answer not in the manual?

Balluff Micropulse BTL5-A series Specifications

General IconGeneral
TypeMagnetostrictive Linear Position Transducer
Operating temperature-40°C to +85°C
Protection classIP67
Housing materialStainless steel or aluminum
Output signalAnalog
Operating voltage10 to 30 VDC
Supply Voltage10 to 30 VDC
Linearity deviation±0.02 % F.S.
Linearity Error±0.02 % F.S.

Summary

Safety Advisory

Proper application

Specifies intended use of the Micropulse transducer in machines with a controller for position measurement.

Wiring

Calibration Procedure

Teach-in

Explains how to replace factory-set null/endpoints by moving the magnet to new positions and pressing buttons.

Manual Adjust

Details setting new start/end values by moving the magnet and using buttons to adjust values, allowing for slope adjustments.

Reset

Describes how to restore the transducer to its original factory default settings.

Teach-in Mode

Teach-in Procedure Steps

Details the sequence of button presses and magnet movements for setting null and end points.

Manual Adjust Mode

Adjust Start Value

Guides on moving the magnet to the start position and holding a button to set the start value.

Adjust End Value

Guides on moving the magnet to the end position and holding a button to set the end value.

Resetting All Values (Reset)

Activate Buttons for Reset

Explains the initial button presses required to prepare for the reset operation.

Perform Reset

Details holding both buttons for 6s to restore factory settings and then releasing them.