4. Troubleshooting
Code 10008: “system - over temperature detected” (Warning)
Situation Solution
The global environment
temperature is too high.
This can generate picture
artefacts.
Check the dust filters, check the fan speeds in communicator. If the
problem persists, escalate the issue including a log package from the
system.
Code 10009: “system - temperature to high on audio DSP” (Warning)
Situation Solution
The temperature measured
on the Audio DSP is too high.
Check the dust filters, check the fan speeds in communicator. If the
problem persists, escalate the issue including a log package from the
system.
Code 10010: “system - temperature to high on ICP FPGA” (Warning)
Situation Solution
The temperature measured
on the ICP FPGA is too high.
Check the dust filters, check the fan speeds in communicator. If the
problem persists, escalate the issue including a log package from the
system.
Code 10011: “system - temperature to high on IMB FPGA” (Warning)
Situation Solution
The temperature measured
on the IMB FPGA is too high.
Check the dust filters, check the fan speeds in communicator. If the
problem persists, escalate the issue including a log package from the
system.
Code 10012: “system - temperature to high o n PPC” (Warning)
Situation Solution
The temperature measured
on the embedded processor
is too high.
Check the dust filters, check the fan speeds in communicator. If the
problem persists, escalate the issue including a log package from the
system.
Code 10014: “formatter - satellite configuration error” ( Error)
Situation Solution
One or more satellite boards
are not configured.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10015: “formatter - satellite hardware mismatch” (Error)
Situation Solution
The three satellites are not of
thesametype.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system.
Code 10016: “formatter - DMD fi le checksum error” (Error)
Situation Solution
The DMD configuration file is
corrupted.
Restart the projector. If the problem persists, escalate the issue
including a log package from the system. An update of the ICMP (in
the same version or in a more recent version) can help restore the
configuration files.