R5911443 /03 UDM186
Ch. Function Value Default Actions
128 - 135 Select input 6: Quad SDI input (if held for 1 second)
12
136 - 143 Select input 7: Quad DP board Input A (if held for 1
second)
13
144 - 151 Select input 8: Quad DP board Input B (if held for 1
second)
13
152 - 159 Select input 9: Quad DP board Input C (if held for 1
second)
13
160 - 167 Select input 10: Quad DP board Input D (if held for 1
second)
13
168 - 175 Select input 11: Quad DP board Inputs A-B (if held for
1 second)
13
176 - 183 Select input 12: Quad DP board quad column mode
(if held for 1 second)
13
184 - 255 Reserved for future functionality
5 Focus (MSB) 0 - 255 128 Set coarse lens focus adjustment
14
6 Focus (LSB) 0 - 255 128 Set fine lens focus adjustment
14
7 Zoom (MSB) 0 - 255 128 Set coarse lens zoom adjustment
14
8 Zoom (LSB) 0 - 255 128 Set fine lens zoom adjustment
14
9 Lens shift vertical
(MSB)
0 - 255 128 Set coarse lens shift in vertical direction
10 Lens shift vertical
(LSB)
0 - 255 128 Set fine lens shift in vertical direction
11 Lens shift
horizontal (MSB)
0 - 255 128 Set coarse lens shift in horizontal direction
12 Lens shift
horizontal (LSB)
0 - 255 128 Set fine lens shift in horizontal direction
13 Light Source
Power
15
0 0 Set light source to 100%
1 - 61 Set light source to value From 100% to 40% in 1%
reductions (e.g. 11 is 90%, 26 is 75%, etc)
64 Set light source to 35%
67 Set light source to 30%
70 Set light source to 25%
73 Set light source to 20%
76 Set light source to 15%
79 Set light source to 10%
80 - 87 Power on / Light source on (If held for 5 seconds)
88- 95 Power down / Light source off (if held for 5 seconds)
96 - 255 Reserved for future functionality
14 Various 0 - 7 0 Reserved for future functionality
8 - 15 Calibrate lens zoom & focus (if held for 5 seconds)
16 - 23 Calibrate lens horizontal and vertical shift (if held for 5
seconds)
DMX chart
14: Only when lens has been calibrated
15: If the Light Source is forced to an output below its minimum value, it will remain at its minimum output value