R5906113 /08 UDX 29
U
+130%
-100%
-40% +40%
D
L R
P
F
U
D
SIDE VIEW
P
F
+130%
-100%
TOP VIEW
P
F
L
R
-40%
+40%
Image 2-10: Vertical and horizontal shift range
P DMD.
F Field of view.
It is mechanical possible to shift outside the recommended field of view, but it will result in a decline
of image quality depending on the used lens and the zoom position of the used lens. Furthermore,
shifting too much in both directions will result in a blurred image corner.
Best image quality is projected in the On-Axis configuration.
Horizontal and vertical projector tilt ranges
The projector can be rotated and mounted at any angle. In other words, you can tilt the projector as much as
desired for your application.
In comparison to lamp-based projectors, the laser phosphor projector also has no limit on side to side tilt.
360°
360°
Image 2-11
Installation preparations