61-101-00802.EF2 (REV. G) CH. 2
January 7, 2015 Page 25 of 44
(50) Press and hold the PRESS TO READ CAP (pF) pushbutton while
adjusting the CAP SIM (pF) control knob to obtain a test set display of
246.0 pF for the UA and UB or 261.0 pF for the UC and UE serial
numbers.
(51) Rotate the TEST FUNCTION switch to IND AMP.
(52) Verify the indicator reads 1200 +/-35 lbs.
(53) Set the test set ON / OFF switch to OFF.
E. Disconnecting / Reconfiguring
(1) Open the circuit breakers.
(2) Disconnect the test set ACFT connector from aircraft wiring plug or
adapter cable.
(3) Disconnect the test set IND connector from the indicator or adapter
cable.
(4) Connect the aircraft wiring plug to the indicator.
(5) Return the aircraft to its original configuration.