Service ManualLast Updated - 9/28/2016
495B SE (S)
80
TWO, THREE AND FOUR PAD PUMP DRIVES
2 PAD PUMP DRIVE 3 PAD PUMP DRIVE 4 PAD PUMP DRIVE
Figure 1
LUBRICANT RECOMMENDATIONS AND FLUID CHANGING PROCEDURES
Lubricant Type:
EP80-90gearuid(exceptfordirectdrivemodels).
Lubricant Grade:
Weather Temperature
Below -10 degrees F (-23 degrees C) = Use 75 W.
Above -10 degrees F and up to 100 degrees F (37.8 degrees C) = Use 80 W/90.
Above 100 degrees F (37.8 degrees C) = Use 85 W/140.
Itisrecommendedthattheuidlevelbecheckeddaily,atthesametimecheckingforuidleaks.
Becausethelubricantsystemistheheartoftheunit,itisespeciallyimportantthattheuidbekeptclean.
The following procedures should be followed:
1. Stopenginebeforecheckingoraddinguid.
2. Check unit for operational warning tags. Heed all warnings.
3. Cleanarounduidllbeforecheckingoraddinguid.
4. Changetheuidafterevery400hoursofoperation.Also,theuidintheunitshouldbechangedwhenever
the uidlevelshowstracesofdirtoreffectsofhightemperature,evidencedbydiscolorationorstrongodor.
5. Draintheuidwhiletheunitisstillwarm,examiningforcontaminationormetalparticles.
(FOR FUNK PUMP DRIVES)