11 Faultscauses and remedies
Information about the configuration of host parameters and barcode types can be found in the
ZEBRA Product Reference Guide.
Please contact BARTEC Automation & Enterprise Mobility Support: Service-
mobilecomputing@bartec.de if none of the solutions set out rectify the fault.
Fault
Possible cause
Solution
Scanner beam does not
appear when the trigger button
is pressed
No power is supplied to the
hand-held scanner
Connect the power supply to the corded
hand-held scanner.
Wrong interface cable is being
used
Connect the correct interface cable.
Hand-held scanner has been
deactivated
Activate the hand-held scanner.
Further information about this can be
found in the ZEBRA Product Reference
Guide.
Scanner beam has been
deactivated
Activate the scanner beam.
Further information about this can be
found in the ZEBRA Product Reference
Guide.
Hand-held scanner emits a
scanner beam, but does not
decode barcodes
Barcode is not legible
1. To test the scan engine, scan
barcodes of the same type.
2. Print the barcode out again if it is
damaged.
Scanner beam is not capturing
the whole width of the barcode
Select the optimal scan
position for the barcode.
Move the barcode into the field
of vision of the hand-held
scanner.
Distance between barcode and
hand-held scanner is wrong
Position the hand-held scanner closer to
or farther away from the barcode.
Hand-held scanner decodes
barcodes, but does not send
these to the host
Hand-held scanner has not
been correctly programmed for
the host type
Program the hand-held scanner for the
host type.
Further information about this can be
found in the ZEBRA Product Reference
Guide.
Interface cable has not been
correctly connected
Connect the interface cable correctly.
Base station has not been
programmed for the host type
Check the host parameters of the hand-
held scanner or change the parameters.
Hand-held scanner is not
connected to the base station
Connect the hand-held scanner to the
base station (see Chapter 8.1.3)

Table of Contents

Other manuals for Bartec BCS36 8ex Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bartec BCS36 8ex Series and is the answer not in the manual?

Bartec BCS36 8ex Series Specifications

General IconGeneral
BrandBartec
ModelBCS36 8ex Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals