EasyManua.ls Logo

Basalte B.link - 3. Configure the B.link in ETS; 3.1 IP configuration

Basalte B.link
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B.link
Manual
5 / 32 v.1.1 © 2014 basalte
3. Configure the B.link in ETS
The B.link network parameters, A/V receivers controlled directly by B.link over IP and the KNX
input/output objects are configured using ETS.
The B.link comes with a configuration software that allows you to configure your own set of IR- and
serial codes, to define the project topology and to create macros (see chapter 5 B.link
Configuration software).
3.1 IP configuration
The B.link network settings need to be specified in the section IP configuration:
IP address of B.link
IP address of the gateway
Subnet mask
Parameter Description
IP address of B.link This parameter defines the static IP address of the B.link
Gateway This parameter sets the IP address of the network default
gateway (router).
Subnet Mask
This parameter defines the subnet mask used.