Testing DECS-250
With the RTM Analysis screen controls, you can:
Select the parameters to be graphed
Adjust the resolution of the graph x axis and the range of the graph y axis
Start and stop plot captures
Open an existing graph file, save a captured plot in a graph file, and print a captured graph
Graph Parameters
Any four of the following parameters may be selected for plotting in the graph areas.
APC Error to PI
APC Integrator state
APC PI output
Auxiliary voltage input (Vaux)
Average line current (Iavg)
Average line-to-line voltage (Vavg)
AVR error signal (Errln)
AVR output
Bus frequency (B Hz)
Bus voltage (Vbus)
Compensated frequency deviation
(CompF)
Control output (CntOp)
Cross-current input (Iaux)
Desired APC Reference
Droop
FCR error
FCR state
FCR output
Field current (Ifd)
Field voltage (Vfd)
Filtered mechanical power (MechP)
Final PSS output (Pout)
Frequency response signal (Test)
FVR error
FVR state
FVR output
Generator frequency (G Hz)
Grid connect state
Grid code test signal
Internal state (TrnOp)
Lead-lag #1 (x15)
Lead-lag #2 (x16)
Lead-lag #3 (x17)
Lead-lag #4 (x31)
LVRT Desired var Reference
LVRT var Reference
Mechanical power (x10)
Mechanical power (x11)
Mechanical power (x7)
Mechanical power (x8)
Mechanical power (x9)
Negative sequence current (I2)
Negative sequence voltage (V2)
Network Load Share
Null Balance Level (Null Balance)
Null Balance State (Null State)
OEL controller output (OelOutput)
OEL reference
OEL state
Phase A current (Ia)
Phase A to B, line-to-line voltage (Vab)
Phase B current (Ib)
Phase B to C, line-to-line voltage (Vbc)
Phase C current (Ic)
Phase C to A, line-to-line voltage Vca
Position Indication (PositionInd)
Positive sequence current (I1)
Positive sequence voltage (V1)
Post-limit output (Post)
Power factor (PF)
Power HP #1 (x5)
Pre-limit output (Prelim)
PSS electrical power (PSSkW)
PSS terminal voltage (Vtmag)
Reactive power (kvar)
Real power (kW)
SCL controller output (SclOutput)
SCL reference
SCL state
SCL PF reference
Speed HP #1 (x2)
Synthesized speed (Synth)
Terminal frequency deviation (TermF)
Time response signal (Ptest)
Torsional filter #1 (Tflt1)
Torsional filter #2 (x29)
Total power (kVA)
UEL controller output (UelOutput)
UEL reference
UEL state
Var limiter output (VArLimOutput)
Var limiter reference
Var limiter state
Var/PF error
Var/PF state
Var/PF output
Washed out power (WashP)
Washed out speed (WashW)