Describes the DECS-150's intended use for brushless AC synchronous generators/motors.
Lists the key capabilities of the DECS-150, including control modes, protection, and communication.
Illustrates and describes the DECS-150 front panel indicators, layout, and USB port.
Details the required operating power voltage, frequency, and sources for the DECS-150.
Describes the excitation power output capabilities of the DECS-150.
Explains machine voltage sensing inputs, connections, and transformer configurations.
Describes machine current sensing inputs, CT compatibility, and connection details.
Explains bus voltage sensing inputs and connections.
Details the four available excitation control modes: AVR, FCR, Var, and Power Factor.
Covers undervoltage, overvoltage, and loss of sensing protection functions.
Details overfrequency and underfrequency protection settings.
Details exciter field current limit, overvoltage, and diode monitoring.
Monitors and limits field current to prevent overheating, with online and offline settings.
Limits excitation to prevent end-iron heating and loss of synchronism.
Limits stator current to prevent overheating by adjusting excitation.
Settings for DECS-150 compatibility with grid code compliant systems.
Manages generating unit ramp rates and output for grid code compliance.
Describes five modes for controlling reactive power output based on voltage or power.
Overview of the BESTCOMSPlus PC application for configuring, monitoring, and managing the DECS-150.
Provides instructions for installing the BESTCOMSPlus software and DECS-150 plugin.
Explains how to save, upload, and download DECS-150 settings and logic files.
Describes the programming method for DECS-150 logic, including objects, composition, and simulators.
Defines system operation through equation-based logic variables.
Details local communication via USB port for configuration and commissioning.
Details the Modbus TCP protocol, message structure, modes, and parameters.
Allows setting the unit's operating mode to generator or motor.
Configures equipment ratings for accurate excitation control and protection.
Establishes usernames and passwords to control access to DECS-150 operations.
Configures time and date display conventions and time zone offsets.
Describes the backup battery for maintaining clock function during power loss.
Enables performance testing and monitoring of AVR and PSS via live data plots.
Verifies overall system response by applying step changes to setpoints.
Describes the Modbus communications protocol employed by DECS-150 systems.
Explains Modbus TCP communication modes and security requirements.
Covers periodic checks for clean connections, capacitor care, and front panel cleaning.
Provides guidelines for storing the DECS-150 in a moisture and dust-free environment.
Troubleshooting steps for issues with BESTCOMSPlus or USB communication.
Addresses common operational problems like voltage buildup and output stability.
Diagnoses and resolves issues related to poor voltage regulation.
Details voltage, frequency, and burden requirements for operating power.
Specifies pickup and time delay for voltage, frequency, and field protection.
Details operating range for temperature, humidity, salt fog, and elevation.
Details the installation process for the BESTCOMSPlus Settings Loader Tool.
Manages product settings files and their associated bar codes.
Provides general usage guidelines for the settings loader tool.