Image Acquisition Control
124 Basler scout
Use Case 3 - Acquisition Start Trigger On - Frame Start Trigger Off
Use case three is illustrated on page 125.
In this use case, the Acquisition Mode parameter is set to continuous. The Trigger Mode parameter
for the acquisition start trigger is set to off and the Trigger Mode parameter for the frame start trigger
is set to on.
Because the acquisition start trigger is set to off, the user does not need to apply acquisition start
trigger signals to the camera. The camera will generate all required acquisition start trigger signals
internally.
Because the frame start trigger is set to on, the user must apply a frame start trigger signal to the
camera in order to begin each frame exposure. In this case, we have set the frame start trigger
signal source to input line 1 and the activation to rising edge, so the rising edge of an externally
generated electrical signal applied to line 1 will serve as the frame start trigger signal.
This type of camera setup is used frequently in industrial applications. One example might be a
wood products inspection system used to inspect the surface of pieces of plywood on a conveyor
belt as they pass by a camera. In this situation, a sensing device is usually used to determine when
a piece of plywood on the conveyor is properly positioned in front of the camera. When the plywood
is in the correct position, the sensing device transmits an electrical signal to input line 1 on the
camera. When the electrical signal is received on line 1, it serves as a frame start trigger signal and
initiates a frame acquisition. The frame acquired by the camera is forwarded to an image processing
system, which will inspect the image and determine if there are any defects in the plywood’s
surface.
For more information about the Acquisition Frame Rate Abs parameter, see Section 7.5.1.1 on
page 93 and for information about setting the parameter, see Section 7.5.1.3 on page 95.