EasyManua.ls Logo

Bauer Mini Verticus - Correction Factor for Cartridge Operating Hours

Bauer Mini Verticus
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MNL-126509
April 4, 2013 Page 61
Figure 4-4 Correction Factor for Cartridge Operating Hours
Figure 4-5 Example Record of Adjusted Operating Hours
°F
[°C x 9/5 +32]
°C
[
(°F - 32) x 5/9]
Correction Factor
50 122 0.21
40
104 0.34
30 86
0.58
20 68 1.00
10
50 1.81
0
32
3.44
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0 °C
10 °C 20 °C 30 °C 40 °C 50 °C
Conversion Factor
32 °F 50 °F 68 °F 86 °F 104 °F 122 °F
Date
Operating
Hours
Ambient Temp.
during Compression +18 °F
Correction
Factor
Adjusted Cartridge Hours
Today Total
10/19/04 8 92°F
(33 °C)
0.5 16.00 16.00
11/01/04 4 45°F
(7.2 °C)
2.25 1.78 17.78
Op hrs
Corr. factor
Total hrs
+Today hrs

Table of Contents

Related product manuals