5. Installation
5.1 Environmental Requirements
Temperature
Storage temperature -10 °C ... +70 °C ( +14 °F ... +158 °F)
Operating temperature + 5 °C (+14 °F) ... see „Heat Transmission“
Humidity
Storage and Operating Humidity 10% ... 90%
Non-condensing
5.2 Heat Transmission
Caution
Device heats up during operation.
Skin irritation possible.
Do not touch the camera during operation.
Caution
Heat can damage the camera. Provide adequate dissipation of heat, to en-
sure that the temperatures does not exceed the values in the table below.
As there are num erous possibilities for installation, Baumer recommends
no specic method for proper heat dissipation, but suggest the following
principles:
▪ operate the cameras only in mounted condition
▪ mounting in combination with forced convection may provide proper heat
dissipation
Measure Point (T) Maximal Temperature
VEXG VEXU
65 °C (149 °F)
VEXG-100 / VEXG-52: 60 °C (140 °F)
65 °C (149 °F)
Figure1►
Temperature measuring
point