56
8.4.8 Frame Counter
The frame counter is part of the Baumer image infoheader and supplied with every image,
if the chunkmode is activated. It is generated by hardware and can be used to verify that
every image of the camera is transmitted to the PC and received in the right order.
8.5 Device Reset
The feature Device Reset corresponds to the turn off and turn on of the camera. This is
necessary after a parameterization (e.g. the network data) of the camera.
The interrupt of the power supply ist therefore no longer necessary.
8.6 User Sets
One user set (0-1) are available for the Baumer cameras of the EX series. User set 0 is
the default set and contains the factory settings. User set 1 is user-specic and can con-
tain any user denable parameters.
The user set are stored within the camera and can be loaded, saved and transferred to
other cameras of the EX series.
By employing a so-called "user set default selector", the user set can be selected as de-
fault, which means, the camera starts up with these adjusted parameters.
8.6.1 VEXG
Parameter
AcquisitionMode LineDebouncerLowTimeAbs
AcquisitionFrameCount Width
AcquisitionStart Height
AcquisitionStop OffsetX
AcquisitionFrameRate OffsetY
TriggerMode BinningHorizontal
TriggerSource BinningVertical
TriggerActivation PixelFormat
ExposureTime TestPatternGeneratorSelector
AcquisitionFrameRateEnable TestPattern
ReadoutMode PixelFormat
Gain TestPatternGeneratorSelector
BlackLevel TestPattern
BrightnessCorrection DefectPixelCorrection
FrameCounter GEV SCPD
LineInverter GEV SCFTD
LineSource FixedPatternNoiseCorrection
LineDebouncerHighTimeAbs

Table of Contents