Procedure (add Defect Pixel to defect pixel list)
1. Start the Camera Explorer. Connect to the camera. Select the prole GenICam
Expert.
2. Open the category LUT Control.
3. Locate an empty Defect Pixel List Index (Defect Pixel List Entry PosX = 0 / De-
fect Pixel List Entry PosY = 0).
Avoid using existing coordinates!
4. Determine the coordinates of the defect pixel. Keep the mouse pointer over the
defect pixel. The coordinates of the defect pixel is displayed in the status bar.
For simplication, you can enlarge the image.
5. Enter the determined coordinates for X (Defect Pixel List Entry PosX) and Y
(Defect Pixel List Entry PosY).
6. Activate the registered Defect Pixel List Index (Defect Pixel List Entry Active =
True).
7. Stop the camera and start them again to take over the updated coordinates.
8. Save your settings in a User Set (Category: User Set Control). Coordinates,
which are not stored in an user set will be lost.