7
Pin assignment (BM4-F-)ENC-07
m for sine cosine encoder with SSI interface, without encoder supply
Pin assignment Pin No. Definition
Female Sub-D 15-pin
1 reserved*
2 reserved*
3 reserved*
4 reserved*
5 SIN + [B+]
6 reserved*
7 COS- [A-]
8 COS+ [A+]
9 SIN- [B-]
10 Clock +
11 Clock -
12 reserved*
13 A_GND
14 Data +
15 Data -
* do not connect
NOTE
The connection cable is not offered by Baumüller Nürnberg GmbH and must be made
by the user, see
ZConstruction guidance connection cable for (BM4-F-)ENC-07on
page 61.