TAM 00682 5
DSC 045-100 07 / 2012
Three-phase synchronous motor English
1.2 Designated purpose
The electric motor must only be used for its designated purpose. In this context, the electric motor
must only be used for the applications described in the technical documentation under strict
observance of all the notes in these Commissioning and Maintenance Instructions.
All assembly, commissioning, maintenance, and operating tasks must be carried out by qualified
personnel only.
Within the context of these safety instructions, qualified personnel refers to persons who are
trained and authorized in the specialized area, who are authorized to set up, assemble,
commission, and operate units, systems, and circuits under application of the applicable safety
standards (EN 50110-1).
Inappropriate conduct can result in serious injury and damage to property.
The electric motor is designed for use in industrial applications
and is subject to a number of
standards
and directives, including the following:
Standards
EN 60034-1, EN 60034-5, EN 60034-6, EN 60034-7, EN 60034-9, EN 60034-11, EN 60034-14
EN 60204-1
Voltage Directive EC
The electric motors in this series fully comply with the requirements of the Low Voltage Directive
EC (conformity).
EMC Directive EC
The operation of the electric motor in accordance with its designated use must comply with the
safety requirements in the EMC Directive EC. The proper installation (e. g. separation of signal
lines and power cables, screened lines and cables etc.) is the responsibility of the erector of the
installation and the system provider. During converter operation the EMC information of the
converter-, encoder- and brake-manufacturer must be observed.
All national, local, and system-specific regulations must also be observed!
The electric motor is designed for the following ambient conditions
:
• Ambient temperature: 0 °C to +40 °C
• Altitude: 1000 m above sea level
• Relative humidity: 5 % to 85 %
Please take note of any deviating details specified on the nameplate or in the technical
documentation. The conditions at the place of utilization must correspond to the details on the
rating plate.
Utilization in areas with potentially explosive atmospheres is prohibited unless the
unit is expressly designed for this purpose (refer to additional notes). Furthermore, the
area surrounding the electric motor must be free of inflammable gas mixtures and
hazardous concentrations of dust.
Live and hot motor parts are inflammable and may cause serious injury and damage
to property.
If, in special cases (for utilization in non-industrial applications), more stringent
requirements are in place, e. g., protection against contact with a child's fingers, these
conditions must be met by the customer when installing the system.