EasyManua.ls Logo

Baumuller SI4000 - Page 44

Baumuller SI4000
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTICE!
Configurable inputs
The inputs 1 to 4 can be occupied as you wan
t with N/C or N/O contacts. The corre-
sponding analysis is carried out in the b maXX safe PLC.
Installation
Operation Manual Safety I/O Terminals SI4000 / SO4000
Document no.: 5.08009.05 Baumüller Nürnberg GmbH
44
of 82
7.1
7.1.5.1 Tested devices
The following list contains devices that were tested together with the SI4000 terminal. The
results only apply for the current device hardware version at the time of testing. The tests
were carried out in a laboratory environment. Modifications of these products cannot be
considered here. If you are unsure please test the hardware together with the safety ter-
minal.
Manufacturer Type Comment
SICK C4000 Safety light curtain
Wenglor SG2-141S045C1 Safety light grids
Leuze lumiflex ROBUST 42/43/44 Safety light barriers
Schmersal BNS250-11ZG Safety switch
ifm GM701S Inductive safety sensor
The tests were carried out as function tests o
nly. The information provided in the respec-
tive manufaturer documentation remains valid.