Diagnostic
Operation Manual Safety I/O Terminals SI4000 / SO4000
Document no.: 5.08009.05 Baumüller Nürnberg GmbH
54
of 82
7.2
7.2 Diagnostic
7.2.1 Diagnostic LEDs SI4000
Figure 13: Diagnostic LEDs SI4000
7.2.1.1 Diag 1 (green)
The Diag 1 LED indicates the state of the FSoE interface.
Flashing Code Meaning
LED illuminated continuously normal operation:
FSoE communication OK
rapid flickering, alternating with 1 flash
pulse
Error in S parameter (Failsafe parameter
rapid flickering, alternating with 2 flash
pulses
Error in I parameter (Individual parameter
rapid flickering, alternating with 3 flash
pulses
Waiting for S and I parameter
rapid flickering, alternating with 4 flash
pulses
S- and I-parameter correct:
Waiting for first host message
rapid flickering, alternating with 5 flash
pulses
Watchdog error
rapid flickering, alternating with 6 flash
pulses
CRC error
rapid flickering, alternating with 7 flash
pulses
Sequence number error
rapid flickering, alternating with 8 flash
pulses
Intermediate state in a sensor
7.2.1.2 Diag 2 (red)
The Diag 2 LED illuminates red if the terminal detects an external supply or cross-circuit.
Once the error has been rectified the LED goes out.