Parameter Description Factory setting
HP062 Energy cost in Hybrid electricity cost in high tarif
Can be set from 0.01 to 2.50 €/kWh
0.13 €/kWh
HP063 Energy cost in Hybrid electricity cost in low tarif
Can be set from 0.01 to 2.50 €/kWh
0.09 €/kWh
HP064 Cost of fossil energy (oil or gas) - price per litre or per m3
Cost of fossil energy (oil or gas) - price per litre or per m
3
Can be set from 0.01 to 2.50 €/kWh
0.90 €/kWh
6.3
COUNTERS /TIME PROG / CLOCK menus
Tab.21
List of sub-menus
Sub-menu Description
CNT COUNTERS
CIRCA Timer programming for the main heating circuit
CIRCB Timer programming for the additional heating circuit B
DHW Timer programming for the domestic hot water circuit
CLK Setting the clock and the date
6.3.1 COUNTERS, TIME PROG, CLOCK \CNT menus
Tab.22 Choosing the menu
Counters Selection
Circuit A counters Choose the EHC-04 menu
Circuit B counters Choose the SCB04-B menu
Counters connected to the opera
tion of the heat pump
Choose the EHC-04 menu
Tab.23 Available counters
Parameter Description Unit EHC-04 SCB04-B
AC001 Number of hours that the appliance has been on
mains power
hours X X
AC005 Energy consumed for central heating kWh X
AC006 Enegy consumed for domestic hot water Wh X
AC007 Energy consumed for cooling Wh X
AC008 Energy delivered for central heating kWh X
AC009 Energy delivered for domestic hot water kWh X
AC010 Energy delivered for cooling kWh X
AC013 Seasonal COP X
AC026 Counter that shows the number of pump running
hours
hours X
AC027 Counter that shows the number of pump starts - X
AC028 Total working time of the first stage of backup hours X
AC029 Total working time of the second stage of backup hours X
AC030 Total startings of the first stage of backup - X
AC031 Total startings of the second stage of backup - X
DC002 Numbers of Domestic Hot Water diverting valve
cycles
- X
6 Settings
30 iMPI V200 7700954 - v03 - 13082018