Parameter Description Unit EHC-04 SCB04-B
DC003 Number of hours during which the diverting valve
is in DHW position
hours X
DC004 Number of compressor start-ups during domestic
hot water production
X
DC005 Number of compressor start-ups X
PC002 Number of compressor start-ups - - X
PC003 Number of compressor operating hours hours X
CODE Enter the installer code to access the following pa
rameters.
X
AC002 Number of hours that the appliance has been
producing energy since last service
hours X
AC003 Number of hours since the previous servicing of
the appliance
hours X
AC004 Number of heat generator starts since the
previous servicing.
X
AC013 Seasonal coefficient of performance X
SERVICE Resetting the maintenance service
CLR: the AC002, AC003, and AC004 counters are
reset to zero.
X
6.3.2 COUNTERS, TIME PROG, CLOCK \CIRCA, CIRCB
and DHW menus
Tab.24
Menu Description
CIRCA TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
CIRCB Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
DHW Timer programming for domestic hot water
06:00 - 23:00 ON
23:00 - 06:00 OFF
6.3.3 COUNTERS, TIME PROG, CLOCK \CLK menus
Tab.25
CLK parameter Unit HMI
HOURS Can be set from 0 to 23 available
MINUTE Can be set from 0 to 59 available
DATE Can be set from 1 to 31 available
MONTH Can be set from 1 to 12 available
YEAR Can be set from 2000 to 2100 available