AWHP 16 TR-2
Seasonal space heating energy efficiency under average climate condi
tions
% 125 121
Water heating energy efficiency under average climate conditions % 106.00 106.00
Sound power level L
WA
indoors
(2)
dB 47 47
Ability to function during off-peak hours
(2)
No No
Rated heat output, under colder - warmer climate conditions kW 4 – 8 7 – 13
Space heating - Annual energy consumption, under colder - warmer cli
mate conditions
kWh
GJ
(1)
3804 – 2580 5684 – 4120
Water heating - Annual energy consumption, under colder - warmer cli
mate conditions
kWh
(3)
GJ
(4)
1432 – 664 1432 – 664
Seasonal space heating energy efficiency, under colder - warmer climate
conditions
% 113 – 167 113 – 161
Water heating energy efficiency, under colder - warmer climate conditions % 72.00 – 154.00 72.00 – 154.00
Sound power level L
WA
outdoors dB 69 69
(1) For gas heat pumps only
(2) If applicable.
(3) Electricity
(4) Fuel
See
For specific precautions on assembly, installation and
maintenance: see the chapter on Safety Instructions.
13.2 Product fiche - Temperature Controls
Tab.35 Product fiche for the Temperature controls
MK2
Class II
Contribution to space heating energy efficiency % 2
13.3 Package fiche
Important
‘Medium-temperature application’ means an application where the
heat pump space heater or heat pump combination heater
delivers its declared capacity for heating at an indoor heat
exchanger outlet temperature of 55 °C.