TX1500 Manual Combined 1Oct03 PSC Page 22 of 31 Matrix
SYSTEM PARAMETERS
Used to program additional settings as follows:
System Parameters 2 :
Displays the 2
nd
page of system parameters.
Menu Timeout :
Number of seconds of inactivity before the menu is automatically exited. Use +/- to cycle through values.
15, 20, 40, 60, 80, 100, 120, 150, 180, 200 or 250 seconds.
Program Timeout :
Number of seconds the keyboard will stay in programming mode after the PROGRAM key is pressed. This is
designed to prevent preset positions from being overwritten accidentally. Use +/- to cycle through values.
15, 20, 40, 60, 80, 100, 120, 150, 180, 200 or 250 seconds. It is recommended that a short time is selected.
Lockout Delay :
Number of seconds that a PTZ control of a camera is locked out after the last movement command. Used to
prevent two keyboards from fightingfor control of the same camera. Use +/- to cycle through values.
3, 5, 8, 10, 12, 15, 20, 30, 40, 60, 80, 100 or 250 seconds. 10 seconds would be an appropriate value.
Display Line :
This allows the Tx1500 status line to be moved up and down slightly on the screen to prevent the Tx1500 text
from being overwritten by the text from say a VCR etc. Use +/- to cycle through values.
0 10, 0 being the top line and 10 the bottom line
Relay 0 Action :
Latching Pressing the keyboards TRIANGLE key will toggle the state of the monitor output card relay.
Momentary The relay will switch whilst the TRIANGLE key is pressed and switch back again when the key
is released.
System Parameters
System Parameters 2
Menu Timeout 200 Seconds
Program Timeout 20 Seconds
Lockout Delay 10 Seconds
Display Line 9
Relay 0 Action Latching