TX1500 Manual Combined 1Oct03 PSC Page 22 of 31 Matrix
SYSTEM PARAMETERS
Used to program additional settings as follows:
System Parameters 2 :
Displays the 2
nd
page of system parameters.
Menu Timeout :
Number of seconds of inactivity before the menu is automatically exited. Use +/- to cycle through values.
15, 20, 40, 60, 80, 100, 120, 150, 180, 200 or 250 seconds.
Program Timeout :
Number of seconds the keyboard will stay in programming mode after the PROGRAM key is pressed. This is
designed to prevent preset positions from being overwritten accidentally. Use +/- to cycle through values.
15, 20, 40, 60, 80, 100, 120, 150, 180, 200 or 250 seconds. It is recommended that a short time is selected.
Lockout Delay :
Number of seconds that a PTZ control of a camera is locked out after the last movement command. Used to
prevent two keyboards from ‘fighting’ for control of the same camera. Use +/- to cycle through values.
3, 5, 8, 10, 12, 15, 20, 30, 40, 60, 80, 100 or 250 seconds. 10 seconds would be an appropriate value.
Display Line :
This allows the Tx1500 status line to be moved up and down slightly on the screen to prevent the Tx1500 text
from being overwritten by the text from say a VCR etc. Use +/- to cycle through values.
0 – 10, 0 being the top line and 10 the bottom line
Relay 0 Action :
Latching – Pressing the keyboard’s TRIANGLE key will toggle the state of the monitor output card relay.
Momentary – The relay will switch whilst the TRIANGLE key is pressed and switch back again when the key
is released.
System Parameters
System Parameters 2
Menu Timeout 200 Seconds
Program Timeout 20 Seconds
Lockout Delay 10 Seconds
Display Line 9
Relay 0 Action Latching
Return