6
F002
Display Update Rate
0 5 Times/Sec
1 10 Times/Sec
●
2 20 Times/Sec
3 40 Times/Sec
F003
Digital Filter
Filter
Environment
Vibration
Response
Speed
0 No stage Weak Bad Fast
11
st
stage
22
ed
stage
33
rd
stage
44
th
stage
55
th
stage
66
th
stage
77
th
stage Strong Good Slow
F004
Set ZERO Range
5
±5﹪of weighing platform
Full Capacity
●
10
±10﹪of weighing platform
Full Capacity
20
±20﹪of weighing platform
Full Capacity
30
±30﹪of weighing platform
Full Capacity
F005
Motion Detection
00 Stable
01 0.5 SEC 1 DIV
02 0.5 SEC 2 DIV
03 0.5 SEC 3 DIV
04 0.5 SEC 4 DIV
05 0.5 SEC 5 DIV
06 0.5 SEC 6 DIV
07 0.5 SEC 7 DIV
08 0.5 SEC 8 DIV
11 1 SEC 1 DIV
●
12 1 SEC 2 DIV
13 1 SEC 3 DIV
14 1 SEC 4 DIV
15 1 SEC 5 DIV
16 1 SEC 6 DIV
17 1 SEC 7 DIV
18 1 SEC 8 DIV
F006
Automatic ZERO
Trackin
Com
ensation
00 OFF
11 1 SEC 0.5 DIV
12 1 SEC 1 DIV
13 1 SEC 1.5 DIV
●
14 1 SEC 2 DIV
15 1 SEC 2.5 DIV
16 1 SEC 3 DIV
17 1 SEC 3.5 DIV
18 1 SEC 4 DIV
21 2 SEC 0.5 DIV
22 2 SEC 1 DIV
23 2 SEC 1.5 DIV
24 2 SEC 2 DIV
25 2 SEC 2.5 DIV
26 2 SEC 3 DIV
27 2 SEC 3.5 DIV
28 2SEC 4 DIV
F007
ZERO & TARE keys Availability
●
0 ZERO & TARE keys always work
1
ZERO & TARE keys only work
when display is STABLE
F008
TARE key Availability
●
0 TARE key always work
1
If the GROSS is negative,
TARE key does not work
F009
Accumulation Availability
0 OFF
1 Stable
2 Manual
3
Control Input--Command
Accumulation (For Modbus)
● 4
Control Input -Command
Accumulation