1
12-24 V
AC-DC
C8
max 5 cm
*
*
MOUNTING & WIRING
POWER SUPPLY
OPENING INPUT
OPENS DOOR
SAFETY INPUT
KEEPS DOOR OPEN
2
RADAR FIELD - OPENING IMPULSE
GREEN
LED
* Output status when sensor is operational
Please make sure the cable conectior is maintained the IP class.
ANGLE
2.2 m
The door control unit and the door cover profi le must be correctly earthed.
SENSOR
GREEN
BROWN
YELLOW
BLACK
WHITE
PINK
GREY
VIOLET
WIDTH
2.2 m
The maximum detection fi eld is 4 m x 2 m.
The width of the radar fi eld varies according
to the mounting height of the sensor.
FIELD SIZE
0
1
2
1
2
0
1
2
3
3
3
+
... L, XL, XXL
0
1
2
1
2
0
1
2
3
3
3
-
XXS, XS, S ...
X
max.
5 cm
C8
H
W
3
1m left
1m right
1m middle
INFRARED FIELD - SAFETY
Spont fi nder LED
WIDTHANGLE
DOOR
RED
RED
LED
* Mask is an accessary.
Max. mounting height: 3 m
AWAY
Measured in optimal
conditions.
Use mask to get different areas
of detection fi eld.
H W
2.20 m 2.20 m
2.50 m 2.50 m
3.00 m 3.00 m
4
SETUP
Dip switch
Assistance
setting
1234
ON
Critical environment/outdoor
* Presence time 5min Push from OFF to
ON,start assistance set up
Reservation
OFF
Indoor Presence time 1min
Step out of the detection fi eld during setup.
+
OPEN+CLOSE
RED-GREEN
OFF
IMPORTANT: Test the good functioning of the installation before leaving the premises.
It is recommended to clean the optical parts at least once a year or more often if required due to
environmental conditions.
* The critical environment/outdoor
sensitivity is decreased, and the immunity
is increased.