Seconds UPS
3.3 Functions
3.3.1 FUNCTION F_GetVersionTcSUPS_CX51x0
This function can be used to read PLC library version information.
FUNCTION F_GetVersionTcSUPS_CX51x0 : UINT
VAR_INPUT
nVersionElement : INT;
END_VAR
nVersionElement : Version element to be read. Possible parameters:
1 : major number
2 : minor number
3 : revision number
Prerequisites
Development environment Target plat-
form
Hardware PLC libraries to include
TwinCAT v2.11R3 Build 2047 or higher
TwinCAT v3.1 Build 4018 or higher
PC (i386) Seconds UPS TcSUPS_CX51x0.Lib
CX51x028 Version: 1.6